1-5/8" vibration absorbers are installed on discharge & suction tubes of reciprocating compressor in cascade heat pump units | Бытовая

Сохраните в закладки:

Цена:US $41.14RUB*

Количество:

Доставка в Эль-Монте, по России и СНГ


  • 1-5/8" vibration absorbers are installed on discharge & suction tubes of reciprocating compressor in cascade heat pump units | Бытовая - Фото №1
  • 1-5/8" vibration absorbers are installed on discharge & suction tubes of reciprocating compressor in cascade heat pump units | Бытовая - Фото №1
  • 1-5/8" vibration absorbers are installed on discharge & suction tubes of reciprocating compressor in cascade heat pump units | Бытовая - Фото №1
  • 1-5/8" vibration absorbers are installed on discharge & suction tubes of reciprocating compressor in cascade heat pump units | Бытовая - Фото №1
  • 1-5/8" vibration absorbers are installed on discharge & suction tubes of reciprocating compressor in cascade heat pump units | Бытовая - Фото №1
  • 1-5/8" vibration absorbers are installed on discharge & suction tubes of reciprocating compressor in cascade heat pump units | Бытовая - Фото №1
  • История цены

    *История изменения цены! Указанная стоимость возможно, уже изменилось. Проверить текущую цену - >

    Месяц Минимальная цена Макс. стоимость Цена
    Aug-17-2025 52.65 руб. 53.79 руб. 52.5 руб.
    Jul-17-2025 42.14 руб. 43.71 руб. 42.5 руб.
    Jun-17-2025 51.17 руб. 52.90 руб. 51.5 руб.
    May-17-2025 51.58 руб. 52.19 руб. 51.5 руб.
    Apr-17-2025 41.43 руб. 42.66 руб. 41.5 руб.
    Mar-17-2025 50.52 руб. 51.80 руб. 50.5 руб.
    Feb-17-2025 50.58 руб. 51.97 руб. 50.5 руб.
    Jan-17-2025 49.39 руб. 50.29 руб. 49.5 руб.

    Новые товары

    Характеристики

    1-5/8" vibration absorbers are installed on discharge & suction tubes of reciprocating compressor in cascade heat pump units | Бытовая

    Описание товара

    The vibration absorbers are designed for installation on commercial refrigerating systems and on civil and industrial air conditioning plants. The function of this item is to avoid the transmission of compressor's vibrations to the refrigerating system pipes, reducing the risk of damage and the noise level. The vibration absorbers can also compensate small thermal expansion of the piping.

    INSTALLATION

    1.) A vibration absorbers can be installed both on suction and discharge lines of a refrigerating system, as close as possible to the compressor. The vibration absorbers are not designed to compensate possible piping misalignment. Vibration absorbers should be installed perpendicularly to the direction of vibrations. When vibrations exist on two planes, two vibrations absorbers should be used, as shown on the fig.. For the maximum absorption of vibrations, the refrigerant line should be anchored at the end of the vibration absorber, as shown on the fig.

    2.) Vibration absorbers can be installed vertically too, because they are designed to avoid the retention of condensing water in the wavy zone near to the connections. So there are no problems to install them with temperatures lower then 0°C.

    3.) Vibration absorbers are not designed to absorb axial or torsion stress. Care should be taken to allow sufficient space for the vibration to avoid static compression or tension, after brazing on place.

    4.) High speed of the refrigerant fluid can produce vibration and noise phenomena. In this case it’s advisable to install a larger size of Vibration Absorber.

    5.) The connection of the vibration absorbers to the piping is normally performed by a brazing process. The specific design and construction of vibration absorbers allows welding without particular protections to prevent overheating.

    WARNING!

    Ensure a gap corresponding to the 2% of the total length of the vibration absorber device to compensate for possible thermal expansion.

    Components in Cooling and Heating



    Трекер стоимости


    Отзывы покупателей

    Новые отзывы о товарах

    Serg 06 Октября 2022, 16:07 #

    please inform us about the opportunity to purchase from you a filter with a fineness of 40 microns and 100... Читать отзыв полностью...

    Юрий Евгеньевич Суворов 13 Апреля 2023, 08:13 #

    Продавец обманывает. Не добросовестный.... Читать отзыв полностью...

    Владимир 07 Мая 2023, 13:50 #

    my height = 183 cm, weight = 93 kg, shoulders = 51 cm, sleeve length = 64 cm. What size... Читать отзыв полностью...

    Alexander Sokolov 14 Мая 2023, 20:29 #

    Why is the GK DRAW A3 Pro graph builder unavailable for purchase in Russia?... Читать отзыв полностью...

    Александр 12 Января 2022, 18:10 #

    В коплекте была инструкция? У меня такой же трекер.. с ним была инструкция, хоть и на английском, но можно разобраться..... Читать отзыв полностью...

    Владимир 03 Апреля 2023, 17:40 #

    Планшет бмах11про просто пушка за эти деньги...... Читать отзыв полностью...

    Иаксим 19 Сентября 2025, 08:11 #

    Работает хорошо, жалко что нет инструкции на русском языке или видеообзора, об использовании. ... Читать отзыв полностью...


    Отзывы о 1-5/8" vibration absorbers are installed on discharge & suction tubes of reciprocating compressor in cascade heat pump units | Бытовая

    Данную страницу никто не комментировал. Вы можете стать первым.
    Введите символы или вычислите пример:
    captcha